CMS Document 13119-v2

JTAG programing adapter for HE CU: DESIGN ERROR

Document #:
CMS-doc-13119-v2
Document type:
Technical Data
Submitted by:
Tullio Grassi
Updated by:
Tullio Grassi
Document Created:
16 Jul 2016, 00:21
Contents Revised:
15 Nov 2016, 05:47
Metadata Revised:
28 Mar 2017, 15:29
Viewable by:
  • Public document
Modifiable by:

Quick Links:
Latest Version

Other Versions:
CMS-doc-13119-v1
19 Aug 2016, 19:06
Abstract:
!!!!!!! THE PCB DESCRIBED HERE HAS A DESIGN ERROR: THE CONNECTOR "X1" FOOTPRINT IS A MIRROR IMAGE OF WHAT IT SHOULD BE !!!!!!!!!

Corrected design: https://cms-docdb.cern.ch/cgi-bin/DocDB/ShowDocument?docid=13292

HE Calibration Unit (CU) JTAG programing adapter card. It is a port that allows JTAG connection to the Calibration Module’s QIE11 A3P1000L after installation in the RBX.

Files in Document:
  • PCB BOM (QIE11 External JTAG _BOM(7-14-2016).xlsx, 11.1 kB)
  • PCB Gerber files (HE_CU_JTAG_PCB_specs_July2016.zip, 98.2 kB)
  • Schematic (QIE11 External JTAG.pdf, 61.5 kB)
Related Documents:
Referenced by:
  • CMS-doc-12746: HE phase-I production Calib Module, Mechanical Design